نتایج جستجو برای: Refrigerant R290

تعداد نتایج: 1960  

2014
Bin Gao Zhenhua Chen Qiang Gao

During the process of refrigerant alternative, R290 (propane), as a nature refrigerant used in Room Air Condition (RAC) system, is thought as a long-team substance and has attracted great attention. This paper simply introduced the characteristics and standard demands of R290 application, then, based on a 1HP R290 DC INV. RAC system at first, then finished the comparison test when a one-cylinde...

2015
Deepak Paliwal

An experimental performance study on VCR system with 100g R600a/R290 refrigerant mixture and 100g R600a (pure isobutene) as drop in replacement of R134a was conducted . continuation running tests were performed under different length of capillary for R600a/R290 & R600a. The result showed that the hydrocarbon mixture (R600a/R290) had highest COP at L=10 feet length capillary by17.35% -23.5% for ...

This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...

2012
A. Baskaran P. Koshy Mathews

A performance analysis on a vapour compression refrigeration system with various refrigerants mixture of R152a, RE170, R600a, and R290 were done for various mixture ratios and their results were compared with R134a as possible alternative replacement. The results showed that all of the alternative refrigerants investigated in the analysis except R431A, [R 152a (29%), R290 (71%)] have a slightly...

2016
Cichong Liu Ziyang Sun Ziqi Zhang Junye Shi Jiangping Chen Cichong LIU Ziyang SUN Ziqi ZHANG Junye SHI Jiangping CHEN

Nowadays, an increasing attention in environmental issues including the global warming effect and ozone layer depletion has been attracted. R22 is urged to be ruled out until 2020 and 2030 for developed and developing countries. R290 (propane) has been regarded as a promising alternative refrigerant for the air-conditionings. However, R290 has different thermo-physical properties than conventio...

Journal: :E3S web of conferences 2023

This paper reports on an experimental study evaluating a window air conditioner's performance when R152a/R290/R600/R600a refrigerant mixture (by various mass percentages) is used as possible alternative to R-22. Alternative refrigerants are local, cheap, and environmentally friendly. Unmodified R-22 AC was charged with R152a/R290/R600/R600a. During the experiment, parameters such coefficient of...

2006
PIOTR A. DOMANSKI DAVID YASHAR

This paper presents an analytical evaluation of isobutane (R600a), propane (R290), R134a, R22, R410A, and R32 in a vapor compression system used for comfort cooling applications. The evaluation method was based on a system simulation model that was complimented with an evolutionary computation module for the optimization of refrigerant circuitries in the evaporator and condenser. The evaluation...

2014
R S Mishra

The methods for improving second law efficiency have been considered in this paper by using liquid vapour heat exchanger is investigated in this paper. Detailed energy and exergy analysis of multi-evaporators at different temperatures with single compressor and single expansion valve using liquid vapour heat exchanger vapour compression refrigeration systems have been done in terms of performan...

2014
Ammar M. Bahman Ray W. Herrick Eckhard A. Groll Travis Horton James E. Braun Ammar BAHMAN Eckhard GROLL Travis HORTON James BRAUN

Air conditioning contributes significantly to building energy consumption in hot climate regions. In addition to greater cooling requirements in hot climates, cooling equipment efficiency decreases with increasing outdoor temperature. Therefore, it is advantageous to develop improved technologies that can achieve higher efficiency at high ambient conditions. In this paper, two novel compression...

Journal: :Journal of Central European Green Innovation 2022

Due to the detrimental environmental consequences of synthetic refrigerants, natural refrigerants have gained renewed interest as alternative for a variety applications due their minimal ozone depletion potential (ODP) and insignificant global warming (GWP). This study compares performance characteristics R32-based Air Source Heat Pump (ASHP) those R290 R410A refrigerants. In this study, analys...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید